Beverage manufacturing
Turnkey safety retrofit of a bulk tipper
- Fault
- A recorded operator injury on a manually operated bulk tipping system.
- Action
- Designed the full motorised retrofit: 400 V supply through isolator, MCB, safety line contactor and VFD to a direct-coupled drive; a dual-channel hard-wired E-stop independent of drive firmware; hold-to-run pendant; travel limits. Compliant safety performance without the cost of a safety PLC.
- Result
- A board-ready package: BS EN 60204-1 schematics, an itemised £675 bill of materials, locked drive parameters and a 62-point validation checklist. The self-audit against SI 2008/1597, PUWER 1998 and BS EN ISO 13849-1 found a UKCA substantial-modification trigger the client's own process had missed.
Start a conversation
Bring the failure that won't stay fixed.
Interim, contract and project engagements across the UK.