Case studies

Case studies.

Each one is written the same way: the fault, the diagnosis, the action, the result, and the basis for every figure. Confidential engagements are anonymised to sector and asset type.

Featured investigation · FMCG aseptic processing

Catastrophic failure of PTFE aseptic valve bellows under hydraulic dead-head transient.

A 54-head aseptic rotary can filler lost over half its valve bellows in a single clean-in-place cycle. The OEM and the CIP integrator each blamed the other. The specimens were read first, five competing mechanisms were eliminated on physical evidence, and a calibrated recorder then confirmed the transient. The result: a six-node evidenced causal chain and a three-tier corrective framework.

Client, supplier and asset identities redacted. Data reproduced unaltered.
11.4 bar Peak hydraulic transient recorded at dead-head
4.6 × Exceedance over the 2.5 bar nominal CIP manifold pressure
82 °C Fluid temperature: PTFE has lost 40–50% of its yield strength
54% Of the bellows population requiring renewal
Engagement archive

Outcomes, with the basis stated.

Royal Mail / Solystic

Independent sign-off at four hubs

Controlled the technical acceptance that released multi-million-pound OEM milestone payments, holding acceptance until punch-list items closed.

7,000+ parcels/hour verified
Unilever · JEWEL

Commissioned to 85% OEE, then restored it

Lead commissioning engineer for a production centre generating £600m+ a year; returned as subject matter expert to reverse the decline.

85% OEE benchmark
FMCG · robotic packer line

Drive fault cleared without changing parts

The OEM rated the fault as an IGBT failure and a nine-hour outage. Knowledge of the drive's internal fault handling had the line at full speed in 35 minutes.

35 min · £172,500 avoided
Food manufacturing

Safety retrofit in four hours

Engineered a dual-channel safety architecture with a monitored reset and installed it in a planned stop. Compliant production within 48 hours of the finding.

48 hours to compliant production
Food processing · CIP

Water recovery doubled

A mass balance found the isolated secondary inlet. Reinstated with staged lead-lag recovery, without chatter or water hammer.

−250 → +100 L/min
AstraZeneca

Pharma line throughput doubled

Redesigned the outfeed to use idle robotic capacity, and held engineering sign-off as technical authority on GMP change control.

2 × throughput
Beverage manufacturing

Turnkey safety retrofit of a bulk tipper

Full motorised retrofit with dual-channel hard-wired E-stop, BS EN 60204-1 schematics, itemised £675 BOM and a 62-point validation checklist.

£675 bill of materials
Start a conversation

Bring the failure that won't stay fixed.

Interim, contract and project engagements across the UK.